Bell System (Telephones) Ltd.BSX DOOR ENTRY TELEPHONE EXCHANGEInstallation and Operation Issue 3.00PLEASE READ THIS MANUAL PRIOR TO INSTALLATION. IF
8allowing a space between the speech unit and the inside surface of the panel (ie grill).The connections affecting the speech operation are CHROT to t
9Technical HelpIf you are experiencing any problems or have any questions regarding the installation pleasecontact the Manufacturers:-Head OfficeBell
10The TS2000 Time-Clock ModuleThis section describes the operation and programming of the TS2000 Time Clock module foruse with the Tradesman’s facilit
11To set the current TIME and DAY:1. Hold and press until the correct day is displayed.2. Hold and press until the correct hour is displayed
12Reviewing the programs:Press each time to toggle through the 8 on and off settings.Manual OverridePress to toggle through ON/AUTO/OFF modes as i
CONTENTS1. Introduction ... 1Control Unit BSX ... 1The Entrance Panel ... 2Model 51 Speech
18
1IntroductionThe BSX Door Entry Telephone System is designed for low rise blocks of flats. It provides themeans for visitors to call an individual res
2The Entrance PanelThis is commonly a model VRP or LCP series panel, being a flush mounting stainless steel(BS316) vandal-resistant panel. The panel
3Installation ProcedureFitting the Control UnitAll of the equipment within the control unit box is mounted on a removable plate. It is importantthat
4Model PSU138 Power SupplyImportant Safety InformationThe Model PSU138 Power Supply must be mounted in a ventilated cabinet/enclosure designedto house
5Connections to the Entrance PanelAll connections to the entrance panel and doors are provided by the control PCB marked 'CTX';if the unit
6Connections to the TelephonesThe telephone connections are provided by the RELAY PCB in the control unit marked 'RLX'.Each relay board
7Testing & TroubleshootingPush-button OperationApply mains power to the control unit and turn on at the fused isolator switch. When a push-button