Bell System BL106 Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ziffernblock Bell System BL106 herunter. CS106 BL106 User Manual (PD-024 Iss 4) Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Door Entry & Coded Entry

C106 Coded Access Keypad Including: CS106 and BL106 Door Entry & Coded Entry PD-024 Issue 4

Seite 2

CS106/BL106 Combined Door Entry and Coded Access 10 Cable Requirements Cable Types 0.5mm: Twisted pair, e.g. BT spec CW1308 or CAT5 UTP 1.0mm: 1.

Seite 3 - Products

CS106/BL106 Combined Door Entry and Coded Access 11 Power Supply - Important Safety Information The Model 340C Power Supply must be wall mounted on t

Seite 4 - Contents

CS106/BL106 Combined Door Entry and Coded Access 12 Mains Cables Use only mains cable to BS6004, BS6500, or equivalent, within the following specifie

Seite 5

CS106/BL106 Combined Door Entry and Coded Access 13 Electric Lock Release When installing lock releases please allow a little movement on the

Seite 6 - General Description

CS106/BL106 Combined Door Entry and Coded Access 14 High Current Lock Releases For a lock release or a magnetic lock rated higher than 0.5A an additi

Seite 7

CS106/BL106 Combined Door Entry and Coded Access 15 Time Restricted Access The C105 Keypad has a pair of terminals marked ‘TIME’ which c

Seite 8

CS106/BL106 Combined Door Entry and Coded Access 16 Programming the C106 Keypad General The 10 access codes, lock time etc, are all programmed via t

Seite 9 - Installation

CS106/BL106 Combined Door Entry and Coded Access 17 Programming a New Access Code (Functions 1 to 10) The C106 Keypad has ten access codes. Each c

Seite 10 - Cable Requirements

CS106/BL106 Combined Door Entry and Coded Access 18 Changing the Security key (Function 91) The security key is the code that must be entered on the

Seite 11

CS106/BL106 Combined Door Entry and Coded Access 19 Choosing an access code To ensure an adequate level of security it is recommended that a minimum

Seite 13 - Electric Lock Release

CS106/BL106 Combined Door Entry and Coded Access 20 Programming the Action Codes (Functions 51 to 60) Each access code has an associated action numbe

Seite 14 - High Current Lock Releases

CS106/BL106 Combined Door Entry and Coded Access 21 No Function Key Sequence Factory Setting 51 Code 1 Action Number 51 ++++ <0-3> # 1 (

Seite 15 - Exit Button

CS106/BL106 Combined Door Entry and Coded Access 22 Programming the Lock Duration (Function 95) This is the duration the lock release will operate fo

Seite 16 - Programming the C106 Keypad

CS106/BL106 Combined Door Entry and Coded Access 23 Programming a Lock Delay Time (Function 96) This function causes a delay (0-99 seconds) to be int

Seite 17

CS106/BL106 Combined Door Entry and Coded Access 24 Programming the Factory Settings (Function 99) In the event of any problems, always return to Fac

Seite 18

CS106/BL106 Combined Door Entry and Coded Access 25 Summary of Program Functions Table 1 - Programming Access Codes No. Function Key sequence Factory

Seite 19

CS106/BL106 Combined Door Entry and Coded Access 26 Table 2 - Programming of Action Codes No Function Key Sequence Factory Setting 51 Code 1 Action

Seite 20

CS106/BL106 Combined Door Entry and Coded Access 27 Table 4 - Programming of Other Functions No Function Key Sequence Factory Setting 91 Security ke

Seite 21

CS106/BL106 Combined Door Entry and Coded Access 28 Commissioning After installation of the C106 unit, follow the two test procedures below; any

Seite 22

CS106/BL106 Combined Door Entry and Coded Access 29 Testing the controller with factory settings Before proceeding with this test ensure that the loc

Seite 23

CS106/BL106 Combined Door Entry and Coded Access 3 Features  Up to 10 codes each of 1 to 8 digits.  Two Time Zones for Staff / Executive operat

Seite 24

CS106/BL106 Combined Door Entry and Coded Access 30 Troubleshooting Use the table below to determine the most probable cause of a fault condition. Sy

Seite 25 - Summary of Program Functions

CS106/BL106 Combined Door Entry and Coded Access 31 Symptom Possible Cause/Remedy button is pressed. Lock release does not operate when Exit Button i

Seite 26

CS106/BL106 Combined Door Entry and Coded Access 32 Programming the Factory Settings with the Test Button In the event of any problems, always return

Seite 27

CS106/BL106 Combined Door Entry and Coded Access 33 Specification for the C106 Controller Lock Output Voltage: Same as Input Voltage Load (maximu

Seite 28 - Commissioning

CS106/BL106 Combined Door Entry and Coded Access 34

Seite 29

CS106/BL106 Combined Door Entry and Coded Access 35 CS106 / BL106 Combined Series Combined Door Entry and Coded Access Keypad

Seite 30 - Troubleshooting

CS106/BL106 Combined Door Entry and Coded Access 36 General Description The CS106 / BL106 series systems are combined Door Entry Telephone and Coded

Seite 31

CS106/BL106 Combined Door Entry and Coded Access 37 Installation of the Door Entry Phone System From an electrical point of view, the combined system

Seite 32

CS106/BL106 Combined Door Entry and Coded Access 38 Cable Planning Cable Requirements

Seite 33

CS106/BL106 Combined Door Entry and Coded Access 39 For optimum clarity of speech it is strongly recommended that this system is installed using twis

Seite 34

CS106/BL106 Combined Door Entry and Coded Access 4 Contents Features ...

Seite 35

CS106/BL106 Combined Door Entry and Coded Access 40 Installation Procedure Connect all items by following the wiring diagram, on page 44 or 45. It

Seite 36 - General Description

CS106/BL106 Combined Door Entry and Coded Access 41 Troubleshooting Use the table below to determine the most probable cause of a fault condition.

Seite 37

CS106/BL106 Combined Door Entry and Coded Access 42 Symptom Possible Cause/Remedy Constant tone/feedback when in use.  Volume adjustment required o

Seite 38 - Cable Planning

CS106/BL106 Combined Door Entry and Coded Access 43 Miscellaneous Problems Symptom Possible Cause/Remedy Telephone will not buzz.  Faulty 'O&

Seite 39

CS106/BL106 Combined Door Entry and Coded Access 44 CS106-1/BL106-1 Wiring (1 Way Combined)

Seite 40 - Installation Procedure

CS106/BL106 Combined Door Entry and Coded Access 45 CS106-N/BL106-N Wiring (Multi-way Combined)

Seite 41

CS106/BL106 Combined Door Entry and Coded Access 46 Wiring Diagram - 2 Door System with the C106

Seite 43

Bell System (Telephones) Ltd. Presley Way, Crown Hill, Milton Keynes MK8 0ET. Tel: 01908 261106 (Sales and Technical Support) FAX: 01908 2611

Seite 44

CS106/BL106 Combined Door Entry and Coded Access 5 Table 2 - Programming of Action Codes ... 26 Ta

Seite 45

CS106/BL106 Combined Door Entry and Coded Access 6 General Description The C106 Coded Access Controller is a high quality, versatile security produ

Seite 46

CS106/BL106 Combined Door Entry and Coded Access 7 time period only. This time period can be determined by a time-clock or manually via

Seite 47

CS106/BL106 Combined Door Entry and Coded Access 8 Programmable Options In addition to the 10 access codes the user may program the following other

Seite 48

CS106/BL106 Combined Door Entry and Coded Access 9 Installation Read carefully all of the information presented in this chapter and then install the

Kommentare zu diesen Handbüchern

Keine Kommentare