CS106/BL106 Combined Door Entry and Coded Access
11
Power Supply - Important Safety Information
The Model 340C Power Supply must be wall mounted on to plasterboard, wood
or a similar non-conductive material, in a protected indoor environment and
close to a 240V AC electrical supply e.g. an electrical cupboard. Connections
to the 240V AC mains supply must be carried out by a qualified electrician or
similar competent person, and made in accordance with accepted safety
practices.
A two pole switch (as provided by a Consumer Unit or Switch Fuse) must be
included to isolate both Live and Neutral during Installation or Maintenance. The
circuit must be protected by a fuse or other current limiting device, rated
according to the capacity of the cable used, up to a maximum of 10A.
Fuse
There is no serviceable fuse inside the model 340C Power Supply. It has an
electronic current / thermal limit which will recover when a fault is removed.