BF Apartment Station Digital Entry System
PD–166 Issue 1 Installation and Operating Manual Page 13 of 48
Cable Distances
Video Controller to BF Apartment Station
Single apartment station
per output or first
apartment station
Single apartment station
+ 3 extensions on each
output, all cable powered
Only Master apartment station
has „Auto display‟;
extensions are daisy-chained
Single apartment station
per output with separately
powered extensions
150m maximum to the cable
powered apartment station;
daisy-chain up to 300m total.
All apartment stations
locally powered with a
340C power supply
Locally powered apartment
stations have „Auto display‟;
extensions are daisy-chained
Door Controller to Video Controller(s)
N.B. maximum length from any camera to any
apartment station must be less than 300m
Panel to BDF-DIG Door Controller
All Systems, each entrance
Option: Door Monitor Switch
Power Supply to Controller
All Systems, each PS4 to BFD-
DIG or BSC4
Total length of any daisy chain
NB. A Cat5 cable has 4-pairs (8 cores)
For larger cable distances please contact manufacturer.