
BF Apartment Station Digital Entry System
PD–166 Issue 1 Installation and Operating Manual Page 19 of 48
BFD-DIG Door Controller Settings
The BFD-DIG is programmed from the panel for all settings.
Security
It is strongly recommended that the Panel Security Code (PSEC) be changed from its
factory setting to prevent unauthorised access. Record the new number carefully as it
cannot be easily changed if lost. It is also recommended that the Phone Programming
Code (PPRG), Coded Access Code (ACOD) and Trades Access Code (TCOD) are all
changed from default even if not used.
To access panel programming without the code requires physical access to the controller
PCB, borrow a jumper from say video gain (remember the setting) and place it on the 5 pin
programming header between pins 1 & 2. Now pressing the test button will enter panel
programming for 30S when the panel security code can be read or set. When the
programming is finished replace the jumper back to its original location.
Panel Programming
To use Panel Programming Mode: -
First type the Panel Security Code (initially [3434]) followed by the call button.
The display will show the first programmable parameter (ACOD), and then alternating
at 1 second intervals will be the value and the parameter name.
Press the door button to step down through the programmable parameters.
Press the reception button to step up through the programmable parameters.
The list rolls over bottom to top and vice versa.
To change a numeric parameter simply type a new 1-4 digit value and then press call.
To change other values simply press call to choose the next value.
To exit Panel Program Mode press cancel.
If no button is pressed for 30 seconds then programming mode will auto-cancel.
Coded access code – must be 4 digits
Trade access code – must be 4 digits
Lock Type: Secr (fail secure), Safe (fail safe)
Camera 2: No (absent), Yes (present)
Trade Function: 0-9 – see table
Door Monitor Polarity: Cwo, Owo
Reception / Porter phone number
Phone programming security code
Ring and Lock Buzz-Tone enable, 4 settings
Allow Cancel button to terminate Call
Bellcall BCP1 compatibility mode
Allows user entry of 12A to call BSC4 output 13
Kommentare zu diesen Handbüchern