C106 Keypad
21
Programming a Lock Delay Time (Function 96)
This function causes a delay (0-99 seconds) to be introduced between the
triggering of the lock release and its operation. Typically, this facility is used
when the keypad is located some distance from the entrance.
Procedure
— Enter the security key.
— Type :
96 * <0-99> #
— Both LEDs flash once
— Exit program mode by
pressing **
Example
96 * 3 #
(3 second delay)
Factory Setting = 0 seconds
C106 Keypad
22
Programming the Factory Settings (Function 99)
In the event of any problems, always return to Factory settings.
Procedure
— Enter the security key.
— Type : 99 * #
— Both LEDs flash once
— Exit program mode by
pressing **
If you have forgotten the
security key see
‘Programming the Factory
Defaults Using the Test
Button’ page 30
No Function Factory Setting
1 Program Code 1 1 2 3 4 5
2 Program Code 2 6 7 8 9 0
3 - 10 Program Codes 3 to 10 Disabled
51 Code 1 Action Number 1 (Operate always)
52 Code 2 Action Number 2 (Operate when Time closed)
53 - 60 Code 3 to 10 Action Numbers 0 (Disabled)
91 Security key 1 2 12
95 Lock Duration 3 seconds
96 Lock Delay 0 (Disabled)
Kommentare zu diesen Handbüchern