CS106 Combined Door Entry and Coded Access
39
Troubleshooting
Use the table below to determine the most probable cause of a fault condition.
Refer also to page 26 for problems with the coded access system (C106
Keypad).
Telephone Problems
Symptom Possible Cause/Remedy
Low Speech Volume
Ž Volume adjustment required on speech
unit.
Ž Speech unit is not tight against the
panel grill.
Ž Panel grill is blocked
Ž More than one telephone is off the
hook.
Ž Speech unit supply voltage is low.
Check 10V - 15V across ‘C’ and ‘H’.
CS106 Combined Door Entry and Coded Access
Symptom Possible Cause/Remedy
40
Constant tone/feedback
when in use.
Ž Volume adjustment required on the
Speech Unit.
Ž Speech Unit is not tight against the
panel grill.
Ž ‘O’ connection between Speech unit
and telephone is open circuit.
Ž Entrance panel and telephone are too
close together.
Ž The entrance panel is surrounded by
reflecting walls.
Ž Panel grill is blocked.
No speech when the phone
is buzzed
Ž Wiring fault on the speech signal
connections ‘R’ or ‘T’: ‘R’ carries the
phone microphone signal to the speech
unit; ‘T’ carries the Speech unit
microphone to the phone.