Seitenansicht 5
C106 Keypad
9
Power Supply - Important Safety Information
The Model 340 Power Supply must be wall-mounted on to plasterboard, wood
or a similar non-conductive material, in a protected indoor environment and
close to a 240V AC electrical supply eg. an electrical cupboard. Connections to
the 240V AC mains supply must be carried out by a qualified electrician or similar
competent person, and made in accordance with accepted safety practices.
A two-pole switch ( as provided by a Consumer Unit or Switch-Fuse) must be
included to isolate both Live and Neutral during Installation or Maintenance. The
circuit must be protected by a fuse or other current-limiting device, rated
according to the capacity of the cable used, up to a maximum of 10A.
Fuse
The transformer is protected by a fuse; always replace this with the correct type
and rating:
T200mA 250V (20mm glass fuse, 200mA, 250V, Time delay, approved to BS
EN 60127 or equivalent)
C106 Keypad
10
Mains Cables
Use only mains cable to BS6004, BS6500, or equivalent, within the following
specified limits:
Minimum Maximum
Conductor Diameter 1.0mm (0.75mm
2
) 2.25mm (4mm
2
)
Cable Diameter 4.0mm 8.0mm
When fitting the cables (both primary and secondary) ensure that the cable entry
cut-outs in the enclosure lid are no larger than necessary for the cable diameter
used and under no circumstances must they be taken beyond the outer cut-out
zones.