Bell System CS106 Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 23
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
C106 Keypad
25
Table 4 - Programming of Other Functions
No Function Key Sequence Factory Setting
91 Security key
91 * <1-8 digits> #
1 2 12
95 Lock Duration
95 * <1-99 secs> #
3 seconds
96 Lock Delay
96 * <0-99 secs> #
0 (Disabled)
99
Program Factory
Settings
99 * #
C106 Keypad
26
Commissioning
After installation of the C106 unit, follow the two test procedures below; any
problems can be diagnosed from the troubleshooting section. Finally program
the required security and access codes (page 15).
Testing The Lock Release Outputs
Ensure that the lock release is connected to the correct output (as shown in the
Wiring diagram on page 7).
Press and hold the C106 Keypad TEST button:
! Both of the Lock Outputs (Fail-
Safe and Fail-Secure) and both red
and green LEDs will illuminate.
! After 5 seconds the LEDs will start
to alternate and the lock output will
stop operating; you should release
the test button at this stage to
avoid programming the factory
settings (see page 30).
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 22 23

Kommentare zu diesen Handbüchern

Keine Kommentare