Testing the controller with factory settings
Before proceeding with this test ensure that the lock release is working correctly
by following the tests on page 26.
Program to factory settings by following the instructions on page 22, 30.
Type in code 1 (1 2 3 4 5) - this should operate the lock release for 3
seconds.
If a time clock is present on the system, manually switch it to OFF and
type code 2 (6 7 8 9 0), nothing should happen. Now manually switch
the time clock to ON and retype code 2 (6 7 8 9 0) - the lock release
should operate for 3 seconds.
Reprogram code 1 to another value by following the instructions under
the heading ‘Programming new access codes’ (page 15); check that the
new code operates the lock release and that the old one does not.
If everything is functioning correctly, reprogram the security key (factory
set to 1212), to maintain security.
Reprogram access codes, action codes and other parameters as required
(pages 14 to 22).
C106 Keypad
28
Troubleshooting
Use the table below to determine the most probable cause of a fault condition.
Symptom Possible Cause/Remedy
When power applied nothing
happens (LEDs do not flash)
Ž Power Supply is overloaded. Remove
externally connected components until
the fault disappears.
Ž Polarity not correct. Measure the
voltage at the C106 (+ , -)
Ž Check Power Supply Fuses. Always
replace with fuses of the correct type
and rating.
Lock release operates in
reverse
Ž Incorrect output has been used;
Transpose connections between Fail-
safe and Fail-secure outputs.
Red and Green LEDs flash
together when attempting to
operate lock-release.
Ž Fail-secure Lock release output is
short-circuited or of an incorrect rating;
temporarily disconnect the lock release
and retry (Green LED on for 3 secons),
test lock release (page 26)