Bell System CS106 Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 23
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
CS106 Combined Door Entry and Coded Access
37
Cable Requirements
For optimum clarity of speech it is strongly recommended that this system is
installed using twisted-pair telephone cable (e.g. type CW1308). Use one of the
pairs for the R & O connection between the speech unit and the telephone.
Connections No. of cores
Core
diameter
Cable
length
Phone 4 + 1 per phone 0.5mm 100M max.
Power Supply 2
0.5mm
1.0mm
up to 15M
up to 50M
Lock release (up to 500mA) 2
0.5mm
1.0mm
up to 5M
up to 25M
Time clock 4 0.5mm 100M max.
Exit 2 0.5mm 100M max.
Trades Button 2 0.5mm 100M max.
In most cases cable length restrictions should not present a problem, however
where longer lengths are required please refer to the manufacturer for advice.
CS106 Combined Door Entry and Coded Access
38
Installation Procedure
Connect all items by following the wiring diagram, on page 42. It is strongly
recommended that a single telephone be connected at a time and fully tested
before proceeding to the next.
Speech adjustment
The model 61 speech units have two pots at the rear for adjustment of speech
levels as follows:
Volume A: Speech level at the Entrance Panel
Volume B: Speech level at the Telephone